SourcingAI

Lab chiller

I have found results from40000+products and10000+suppliers aboutLab chiller

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Electric Thermostatic Water Bath
Piston Refrigeration Machinery
Type: Water-Cooled
Type: Air-Cooled
Injection Blow Molding
Application: Industry
Customized: Customized
Certification: CE
Structure: Portable
Material: Steel
Sealing Method: Semi-Closed
Cooling Mode: Air-Cooled
Cooling Method: Water-cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 2
Application Fields: Pharmaceutical
CNC Machine Tools
Condition: New
Noise Level: Low
System Type: Open System
Fans Species: Frequency Fan
Plastic Type: Thermoplastic
Plasticizing Way: Plunger Type
Clamping Way: Mechanical
Automation: Automatic
Computerized: Non-Computerized
Noise: 40-60db
Control Mode: Button
Regenerative Heat Exchanger
Style: Steel Type
Application: School
Application: Hospital
Application: Lab
Application: Industrial
Application: Cooler
Customized: Non-Customized
Certification: ISO
Certification: RoHS
Certification: CCC
Certification: UR
Certification: ISO9001:2008
Certification: GMP
Certification: QS
Certification: ISO9001
Structure: Desktop
Structure: Vertical
Material: Stainless Steel
Cooling Method: Air-cooled
Unit Structure: Split
Selected Voltage: 220V/50HZ
Compressor Number: 1
Application Fields: Chemical
Application Fields: Plastic
Application Fields: Machinery
Application Fields: Food Processing
Application Fields: Electroplating
Precision Machine Tool
Application Machine: Combination machine
Application Machine: Machining Center
Noise Level: Ultra Low
Noise Level: Ultra Quiet
Noise Level: Ordinary

Sourcing guidance for Lab Chiller

What are the key technical specifications to consider when selecting a lab chiller?

When sourcing a lab chiller, you must prioritize cooling capacity (measured in Watts or BTU/h) to ensure it can handle the heat load of your equipment. Key specs include temperature stability (ideally ±0.1°C to ±0.5°C), pump pressure/flow rate to ensure adequate circulation, and the temperature range (e.g., -20°C to +40°C). Additionally, verify the refrigerant type to ensure it meets environmental standards like GWP (Global Warming Potential) regulations.

Which compliance standards and certifications are mandatory for international laboratory equipment?

For B2B buyers, ensuring the product has CE marking is essential for the European market, while UL or ETL certification is critical for the North American market to ensure electrical safety. Since these units often use pressurized systems, look for ISO 9001 quality management systems and compliance with the Pressure Equipment Directive (PED). For medical or specialized lab use, ISO 13485 may be required.

How does the cooling method (Air-cooled vs. Water-cooled) impact procurement decisions?

Air-cooled chillers are easier to install and more mobile but require well-ventilated spaces and can increase ambient room temperature. Water-cooled chillers are more energy-efficient and quieter for high-capacity needs but require a permanent cooling water supply or cooling tower infrastructure. Your choice should depend on the facility's utility capabilities and the total cost of ownership (TCO) regarding water vs. electricity consumption.

What maintenance and durability features should a high-quality lab chiller possess?

Look for units with stainless steel reservoirs and piping to prevent corrosion. Essential safety features include over-temperature alarms, low-liquid level sensors, and high-pressure compressors cut-offs. A high-quality supplier on Made-in-China.com should provide a removable condenser filter for easy cleaning, which significantly extends the lifespan of the compressor.

Cross-Border Procurement & Risk Management for Lab Chillers

What are the primary risks when shipping high-precision lab chillers internationally?

The main risks are refrigerant leakage and compressor damage due to vibration. Ensure the supplier uses seaworthy wooden crate packaging with shock-absorption materials. Furthermore, check if the chiller is shipped with refrigerant; if so, it is classified as Dangerous Goods (Class 9), requiring specific MSDS (Material Safety Data Sheet) documentation and higher freight costs. Many buyers prefer shipping 'dry' (without gas) and charging it locally to simplify customs.

How should I negotiate with suppliers on Made-in-China.com to ensure transaction security?

Always request a factory audit report or a video inspection of the production line. Use Secured Trading Services offered by the platform to protect your payment until the goods are shipped. Negotiate a warranty period of at least 12-24 months and insist on a spare parts kit (seals, fuses, sensors) to be included in the initial bulk order to minimize downtime in case of minor failures.

What should be considered regarding voltage and plug compatibility for different regions?

This is a common pitfall in cross-border sourcing. You must explicitly confirm the voltage (110V, 220V, or 380V) and frequency (50Hz or 60Hz) requirements of your destination country. Requesting the wrong configuration can lead to motor burnout or equipment inefficiency. Ensure the supplier provides the correct industrial plug type (e.g., NEMA for USA, Schuko for EU) before the final assembly.

Related queries