Hplc vial
I have found results from10000+products and4000+suppliers aboutHplc vial
Lab 4ml Glass Clear HPLC Vial with 13-425 Plastic Screw Cap and Septa V1317 100PCS/Pack
OEM Aijiren 8-425 Screw Cap Glass HPLC Vials for LC-Ms GC-Ms
1.5ml 2ml Autosampler Vial HPLC Sample Vials Price
HPLC Vials Screw Glass Bottle with Clear and Amber
Alwsci 1.5ml Clear HPLC Snap Neck Autosampler Glass Vials for Chromatography Analysis
Alwsci Micro ND11 2ml Amber/Clear Snap Neck Glassware HPLC Vials with Patch
Alwsci 2ml ND8 Septa Glass Screw Neck Amber Vial for HPLC
HPLC Vial Chromatography 2ml Amber Glass 12X32mm 9-425 Screw Autosampler Vial
HPLC Chromatography 2ml Crimp High Recovery Vial Clear for Lab Using
Alwsci Agilent HPLC Autosampler Vial ND9 1.5ml 2ml Clear Glass Vial with Writing Area
Alwsci 9-425 HPLC PP Vial Micro Insert IC Testing Laboratory Glassware
Clear 2ml Autosampler Vials with Caps Chromptochrpy HPLC Vials Clear Sample Vial with Screw Caps
2ml 9mm Short Thread Glass Vial Screw HPLC Autosampler Vial
2ml Transparent Pharmaceutical Lab Chromatography Glass HPLC Vials
Manufacturing 10ml 20ml HPLC Vials Chromatography Autosampler Vials Laboratory Detection Headspace Vials
Clear Transparent 2ml Autosampler Vials with Caps Chromptochrpy HPLC Vials Clear Sample Vial with Screw Caps
Laboratory Glass Septa Vial with Screw Cap for Sample Storage and Gc HPLC Analysis
Chine Factory Graduated Glass HPLC Bottle Vials for Laboratory
1.5ml Clear Glass HPLC Vials W Write Spot 9mm Wide Opening Vial Chromatography Vial
Lab 2ml Chromatography Vials Borosilicate Glass Autosampler Vial 1.5ml HPLC Vial
2ml Clear HPLC Vials with Write Spot 9mm Wide Opening Chromatography Vial
300UL Lab 9-425 Screw Autosampler Micro-Vial Integrated Inserts with Label for HPLC
1ml Glass Tuber Shell Vial with PE Plug for Chromatography HPLC System
Sourcing guidance for Hplc Vial
What are the key material specifications to consider when selecting HPLC vials?
The most critical factor is the glass type. You should prioritize USP Type I Borosilicate glass (33-expansion or 51-expansion) to ensure low metal content and high chemical resistance. For light-sensitive samples, Amber glass is essential to prevent photodegradation. If working with proteins or low-concentration analytes, consider Low Adsorption (Deactivated) vials to minimize sample loss due to surface binding.
How do I choose the correct septa and cap combination for my application?
The choice depends on your solvent and needle type. PTFE/Silicone septa are the industry standard for general use, offering excellent resealability. For aggressive solvents like alkanes or ethers, PTFE/Red Rubber is a cost-effective alternative for single injections. Ensure the cap is compatible with your autosampler (e.g., 9-425 screw thread is standard for Agilent, while 11mm crimp or snap caps are common for other brands).
What compliance standards should a professional B2B buyer verify?
Suppliers should provide evidence of ISO 9001 certification for quality management. For pharmaceutical and high-precision labs, look for Certificate of Analysis (CoA) for each batch, confirming dimensions and cleanliness. Ensure the products meet USP and EP (European Pharmacopoeia) standards for hydrolytic resistance to avoid leaching issues during analysis.
How can I evaluate the technical compatibility of vials with my laboratory equipment?
Verify the vial dimensions (typically 12x32mm) and the neck finish. Use robotic-compatible screw caps if using high-throughput automated systems to prevent mechanical jams. For small volume samples, check if the supplier offers integrated micro-inserts which provide better alignment and higher recovery than loose inserts.
Cross-Border Procurement & Risk Management for HPLC Vials
What are the primary risks when importing glass consumables internationally?
The biggest risks are breakage during transit and chemical contamination. You must mandate double-wall corrugated export packaging with internal dividers. To prevent contamination, ensure vials are shrink-wrapped in clean-room environments before being boxed. Request a small trial shipment to test the supplier's packaging integrity before committing to a full container.
How should I negotiate with suppliers on Made-in-China.com for bulk orders?
Focus on Tiered Pricing and Quality Consistency. Ask for a price break at the 10,000, 50,000, and 100,000 unit levels. Instead of just pushing for the lowest price, negotiate for free replacement of damaged goods and a guaranteed lead time (typically 15-25 days). Requesting pre-shipment samples from the actual production batch is a standard professional safeguard.
What are the best practices for shipping and customs clearance for lab consumables?
Ensure the HS Code (typically 7017.90) is correctly declared to avoid customs delays. For shipping to the US or EU, verify if the supplier is familiar with ISF filing or VAT/EORI requirements. For high-value or urgent batches, Air Freight is recommended to reduce handling, but for bulk stock, Sea Freight (LCL/FCL) is more economical if the packaging is robust.
How can I ensure transaction security and supplier reliability?
Utilize the Secured Trading services provided by Made-in-China.com to protect your payment until delivery. Prioritize Audited Suppliers who have undergone third-party onsite inspections by SGS or Bureau Veritas. Always verify the supplier's export history to your specific country to ensure they understand your local regulatory landscape.