Dissolved oxygen meter
I have found results from10000+products and5000+suppliers aboutDissolved oxygen meter
China Factory Wholesale Dissolved Oxygen Meter and Analyzer Water Quality Do Meter
Reliable Dissolved Oxygen Meter Electrode for Water Quality Monitoring
Hach Ldo Dissolved Oxygen Meter and Probe System for Dissolved Oxygen Measurement
Low Cost Dissolved Oxygen Meter Do Sensor Water Measuring Device
Boqu Dog-2092 Hot Sale 4-20mA Price Word Water Dissolved Do Oxygen Meter
Benchtop Do Meter Digital Dissolved Oxygen Meter with Atc for Water Quality Testing
Dissolved Oxygen Meter 0-19.9mg/L for Fish Pond Farm Aquaculture Meter
Multiparameter Digital Water Quality Meter pH ORP Conductivity RS485 Dissolved Oxygen Sensor
Online Dissolved Oxygen Meter Do Analyzer for Industrial Water Treatment System
Handheld Portable Dissolved Oxygen Meter DO Meter
CE Water Testing Kit Dissolved Oxygen Controller Do Meter for Aquaculture and Aquarium with Sensor
Membrane Dissolved Oxygen Meter Industrial Online Polarography Sensor Electrode
Benchtop Laboratory Digital Do Meter Dissolved Oxygen Meter
Smart Water TDS Portable Digital Dissolved Oxygen ORP pH Meter Medidor Pen
Smart pH Meter with RS485 Communication for Wastewater/Hydroponic Dissolved Oxygen/Temperature Multi-Parameter
Yosemitech Y600-a&Y507-a Portable Dissolved Oxygen Meter
Portable Multiparameter pH ORP Conductivity TDS Salinity Dissolved Oxygen Meter Chloride Water Analyzer
Seko K100 Online Dissolved Oxygen Conductivity Chlorine pH Meter
High-Quality Affordable Online Dissolved Oxygen Meter for Water Testing
Gwq-Do280 Digital Aquaculture Analyzer Online Dissolved Oxygen Meter
Sourcing guidance for Dissolved Oxygen Meter
How to choose the right sensor technology for a Dissolved Oxygen (DO) Meter?
Buyers must choose between Optical (Luminescence) and Electrochemical (Polarographic/Galvanic) sensors. Optical sensors are highly recommended for long-term stability and low maintenance as they do not require membrane replacement or electrolyte refills and are not affected by H2S interference. Electrochemical sensors are more cost-effective for occasional spot-checking but require regular calibration and a constant flow of water across the membrane to provide accurate readings.
What are the key technical specifications to verify for industrial or laboratory use?
Ensure the device features Automatic Temperature Compensation (ATC), as oxygen solubility varies significantly with temperature. For high-accuracy requirements, look for Salinity and Barometric Pressure Compensation. The measurement range should ideally cover 0 to 20 mg/L (or 0-200% saturation) with an accuracy of ±1% or ±0.1 mg/L. For field use, an IP67 waterproof rating is essential to prevent damage from accidental submersion.
Which compliance standards and certifications are necessary for international trade?
Suppliers should provide CE certification for the European market and FCC for the US. For environmental monitoring or laboratory applications, check for ISO 9001 manufacturing standards and compliance with EPA-approved methods (like ASTM D888-12). If the meter is used in hazardous environments (e.g., oil & gas), ATEX or IECEx explosion-proof certification is mandatory.
What are the typical usage scenarios and how do they affect product selection?
Aquaculture and Fish Farming require portable, rugged meters with long battery life for daily pond checks. Wastewater Treatment Plants prioritize online, continuous monitoring systems with 4-20mA or RS485 Modbus outputs for integration into PLC systems. Laboratory Research demands high-precision benchtop models with data logging capabilities and USB/Bluetooth connectivity for easy data export.
Cross-Border Procurement Considerations for DO Meters
What are the common risks when sourcing high-precision instruments from overseas?
The primary risk is sensor degradation during transit or receiving a unit with a depleted electrolyte/expired membrane. Always request calibration certificates dated within 6 months. To mitigate risks, use Made-in-China.com's Secured Trading services to ensure the product meets technical specifications before final payment is released.
How should I negotiate with suppliers regarding consumables and maintenance?
DO meters are 'razor-and-blade' products. Negotiate for a bundle that includes extra sensor caps, membranes, and electrolyte solutions (for electrochemical models). Ask for a guaranteed supply of replacement parts for at least 5 years to avoid equipment obsolescence. For bulk orders, request a 2-3% spare parts allowance included in the initial price.
What are the shipping precautions for sensitive electronic sensors?
Sensors are sensitive to extreme temperatures and physical shock. Ensure the supplier uses anti-static packaging and shock-absorbent foam. If the meter includes a lithium battery, the supplier must provide a UN38.3 test report and MSDS to comply with international air freight regulations. For optical sensors, ensure they are stored in a moist environment (hydration bottle) during shipping to prevent the sensing element from drying out.
How can I verify the credibility of a Chinese manufacturer for scientific instruments?
Prioritize 'Audited Suppliers' on Made-in-China.com, as they have undergone third-party verification of their facilities. Request a video factory audit to see their calibration lab and QC testing area. A reliable manufacturer should be able to provide OEM/ODM customization and have a dedicated technical support team for troubleshooting via email or video call.