Dc high voltage generator
I have found results from100000+products and50000+suppliers aboutDc high voltage generator
3.3kv 6kv 6.6kv High Voltage DC Diesel Power Generator 5000kVA-2000kVA with Perkins/Cummins Engine
3.3kv 6kv 6.6kv High Voltage DC Diesel Power Generator 800-2250kVA with Perkins Engine
30kw 50kw Low Speed High voltage Alternative Energy Generators Pmsg DC System
Zgf 60kv to 400kv DC High Voltage Generator, DC Hv Generator
400kv 5mA Electrical Test Equipment Portable DC High Voltage Generator
Portable DC Pressure Withstand Dielectric High Voltage Hv Hipot Generator 120kv/2mA
DC Pressure High Voltage Hv Hipot Withstand Dielectric Generators
GDZG-300-80kV-10mA 80kV, 10mA DC Hipot Test Set High Voltage Generator
High Voltage DC Booster Generator 60kv to 200kv Power Supply
100kv 10mA Portable Intelligent DC Hv Generator High Voltage DC Hipot Generator
China High Tension 60kv 5mA Series DC High Voltage Generator
120kv 2mA Hipot Withstand Voltage Tester DC High Voltage Generator
High Voltage Generator 1800kw 2000kw 2500kVA DC Equipment Power Supply Generators
Zgf DC Pressure Withstand Dielectric High Voltage Hv Hipot Generator
High Voltage 80kV DC Generator for Electrical Testing
3.3kv 6kv 6.6kv High Voltage DC Diesel Power Generator 1000-2250kVA with Perkins Engine
Zgf-400kv5ma DC High Voltage Generator with-1-Year-Warranty
80kVA 100kVA DC High Voltage Diesel Generator Price
DC High Voltage Generator with Leakage Current Price
High Voltage DC Generator 120kv 5mA for Industrial Use
60kv/5mA Intelligence DC High Voltage Hipot Tester Impulse Hv Generator
Sourcing guidance for Dc High Voltage Generator
What are the key technical specifications to evaluate when sourcing a DC High Voltage Generator?
Buyers must prioritize Voltage Stability (Ripple Factor), which should ideally be ≤0.5% to ensure precision in testing. The Voltage Measurement Accuracy should reach ±(1.0% reading + 2 digits). Additionally, verify the Rated Output Voltage (e.g., 60kV, 120kV, or 300kV) and Rated Current to ensure they meet your specific insulation testing or electrostatic application requirements. Look for units featuring ZGF (Zero-crossing Voltage Start) technology to protect both the equipment and the operator.
Which safety and compliance standards are mandatory for international procurement?
Ensure the product carries the CE Mark for European market access and complies with IEC 60060 (High-voltage test techniques). For the North American market, UL or ETL certification is preferred. The manufacturer should hold an ISO 9001:2015 quality management certification. It is critical that the device includes Over-voltage, Over-current, and Zero-start protection mechanisms to prevent catastrophic failure during dielectric strength tests.
How does the cooling system and structural design impact long-term reliability?
For high-power applications, choose generators with Oil-immersed or SF6 gas-insulated high-voltage cylinders for superior heat dissipation and insulation. For portable field testing, Dry-type (Epoxy resin) cylinders are preferred due to their lightweight and leak-proof nature. Ensure the control box and the voltage doubler are modularly designed to facilitate easier maintenance and component replacement.
What are the typical usage scenarios for industrial-grade DC High Voltage Generators?
These units are primarily used for DC withstand voltage tests and leakage current measurements of power cables, surge arresters, and power transformers. They are also essential in electrostatic spraying, dust precipitation, and scientific research involving particle acceleration. Selecting a model with a polarity switching function is vital if your testing protocols require both positive and negative high-voltage outputs.
Cross-Border Procurement Strategy & Risk Management
How can I mitigate the risks of purchasing high-precision electrical equipment from overseas?
Utilize Made-in-China.com's 'Secured Trading' services to ensure payment is only released upon confirmation of receipt. Request a Factory Acceptance Test (FAT) video or hire a third-party inspector (like SGS or Intertek) to verify the actual output voltage against the digital display before the balance payment is made. This prevents receiving 'hollow' units that do not meet rated specifications.
What are the best practices for shipping sensitive high-voltage equipment internationally?
Due to the sensitive electronics and potential pressurized gas (if SF6 is used), the equipment must be packed in IPPC-certified fumigated wooden crates with shock-absorbent foam lining. Clearly label the package as 'Fragile: Precision Instrument'. For air freight, ensure the supplier provides a Non-Dangerous Goods Declaration if the unit contains oil or gas, as these are subject to strict IATA regulations.
How should I negotiate technical support and warranty terms with a foreign supplier?
Negotiate a minimum 24-month warranty period. Since returning heavy high-voltage cylinders is costly, insist on a clause where the supplier provides free replacement PCB boards or control modules via express air courier in case of failure. Demand English-language operation manuals and, if possible, video-call technical training as part of the purchase agreement to ensure your local engineers can calibrate the device correctly.
What customs and trade policy factors should be considered?
Check the HS Code (typically 8543.70) for import duties in your country. Be aware of Anti-Dumping Duties that may apply to specific electrical components. Ensure the supplier provides a Certificate of Origin (CO) to take advantage of any Free Trade Agreements (FTA) that could significantly reduce your total landed cost.