Capillary thermometer
I have found results from2000+products and1000+suppliers aboutCapillary thermometer
Capillary Analog and Digital 4" 100mm Dial Thermometer Guages for Remote Reading
Industrial Stainless Steel Pressure Type Digital Display Thermometer Capillary Thermometer
Capillary Temperature Gauge-Gas Filled Temperature Gauge-Mechanical Thermometer
Industrial Stainless Steel Thermometer, Remote Temperature Gauge with Capillary
Mechanical Temperature Gauge-Capillary Thermometer-All Stainless Type
Industrial 100mm SS304 Gas Filled Vibration Resistant Capillary Thermometer
100mm 0-120℃ Oil Filled Remote Reading Capillary Tube 5 Meter Length Industrial Dial Thermometer
Factory Product Stainless Steel Capillary Remote Electrical Contact Pressure Type Thermometer
Industrial Capillary Thermometer, -20-80°C, 6m Capillary, 100mm Dial, 1/2 NPT
Light Weight All Sizes Temperature Instruments Gas Boiler Capillary Thermometer Dial Insert 37mm Thermometer
Ss Case Dial 63mm Water Heater Temperature Gauge Ss Capillary Thermometer with Ss Front Flange
Back Front Flange Air Condition Full Stainless Steel Capillary Thermometer
Chrome-Plated Ring Dial Plastic Capillary Thermometer 0-120 Used on Bolier with PVC Coated Capillary
Black Case White Printing 0-120c Capillary Thermometer Bolier Use
Lt-148-a Thermometer with Capillary for Water Heater
Lt-147 Capillary Thermometer with 1m Capillary Length 0-120c
High-Quality Plastic Housing Black Capillary Thermometer 0 - 120°C
Bimetallic Capillary Stainless Steel Thermometer Industrial Temperature Gauge
High Quality Stainless Steel Capillary Remote Reading Thermometer
Enclosure Rating IP55 Capillary Thermometer with Lens Glass
6" (150mm) Capillary Thermometer with Bottom Connection, Rear Flange
Capillary Thermometer with Thread 3/8"Bsp Swivel
2.5" (60mm) Capillary Thermometer with Case SS304
2.5" Dial Capillary Thermometer with Bottom Connection
Dial Size 2" (57mm) Capillary Thermometer with Case Black Plastic
Sourcing guidance for Capillary Thermometer
What are the key technical specifications to consider when selecting a capillary thermometer for industrial use?
When sourcing capillary thermometers, you must prioritize measurement range, capillary length, and bulb dimensions. Ensure the temperature range covers your operational needs with a safety margin of at least 25%. The capillary tube should be made of 304 or 316 stainless steel for corrosion resistance, and for high-vibration environments, specify silicone oil filling to dampen needle movement and extend the device's lifespan. Accuracy classes should ideally meet Class 1.0 or 1.6 (EN 13190 standards).
How do I ensure the product meets international compliance and safety standards?
Verify that the supplier provides CE marking for the European market or UL certification for North America. For pressurized systems, compliance with the Pressure Equipment Directive (PED) is essential. If the thermometer is used in food processing or medical fields, ensure the materials are FDA-compliant and the instruments are NSF certified. Always request a Calibration Certificate (ISO/IEC 17025) to validate the accuracy of the sensors before shipment.
What are the common usage scenarios and how do they affect material choice?
Capillary thermometers are ideal for remote reading applications where the display needs to be away from the heat source. For HVAC systems, copper capillaries are often sufficient and cost-effective. However, for petrochemical or marine environments, armored capillaries (PVC or stainless steel spring coating) are required to prevent mechanical damage. In the food industry, a thermowell should be used to allow for instrument replacement without draining the system, ensuring hygienic integrity.
What integration capabilities should I look for in modern capillary thermometers?
For B2B buyers looking to integrate with IoT or PLC systems, consider thermometers equipped with electric contact switches or 4-20mA signal output transmitters. This allows for automated process control and remote monitoring. Ensure the mounting style (e.g., surface mount, panel mount, or flange mount) is compatible with your existing equipment housing to avoid additional machining costs.
Cross-Border Procurement & Risk Management for Capillary Thermometers
What are the primary risks when purchasing capillary thermometers from overseas suppliers?
The biggest risk is capillary breakage or kinking during transit, which renders the gas-actuated or liquid-filled system useless. To mitigate this, mandate specialized shock-absorbent packaging and clear 'Fragile' labeling. Another risk is calibration drift due to extreme temperature fluctuations during sea freight; therefore, you should perform a post-arrival inspection and recalibration check.
How can I negotiate better terms and ensure transaction security with suppliers on Made-in-China.com?
Utilize the Secured Trading Service on Made-in-China.com to ensure payments are only released upon confirmation of receipt and quality. When negotiating, leverage volume-based pricing; for orders exceeding 500 units, you can typically negotiate a 10-20% discount. Request a Gold Member supplier status check and prioritize those with Audited Supplier reports to verify their factory capacity and export history.
What logistics and shipping strategies are best for sensitive measuring instruments?
For high-precision thermometers, Air Freight is recommended to minimize the duration of exposure to harsh shipping conditions, despite the higher cost. If using Sea Freight (FOB or CIF), ensure the supplier uses vacuum-sealed moisture-proof bags to prevent corrosion of the dial and internal mechanisms. Always clarify the Incoterms clearly in the contract to define exactly where the risk transfers from the seller to the buyer.
What should be included in the quality inspection process before final payment?
Hire a third-party inspection agency to perform a 'Random Sampling Test.' The inspection should focus on leakage tests of the capillary, accuracy verification at three different temperature points, and a visual check for dial clarity and casing finish. Ensure the serial numbers on the calibration certificates match the physical units delivered.





























